 PD-2.508 rev. A 12/98
HEXFRED
Features
HFA120MD40D
Anode 1 AC Cathode 2
TM
Ultrafast, Soft Recovery Diode
VR = 400V VF(typ.) = 0.9V IF(AV) = 120A Qrr (typ.) = 420nC IRRM(typ.) = 9.3A trr(typ.) = 36ns di(rec)M/dt (typ.) = 260A/s
Reduced RFI and EMI Reduced Snubbing Extensive Characterization of Recovery Parameters
Isolated Base
Description
HEXFRED diodes are optimized to reduce losses and EMI/RFI in high frequency power conditioning systems. An extensive characterization of the recovery behavior for different values of current, temperature and di/dt simplifies the calculations of losses in the operating conditions. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for power converters, motors drives and other applications where switching losses are significant portion of the total losses.
TM
Absolute Maximum Ratings (per Leg)
Parameter
VR IF @ TC = 25C IF @ TC = 100C IFSM EAS PD @ T C = 25C PD @ TC = 100C TJ TSTG Cathode-to-Anode Voltage Continuous Forward Current Continuous Forward Current Single Pulse Forward Current Non-Repetitive Avalanche Energy Maximum Power Dissipation Maximum Power Dissipation Operating Junction and Storage Temperature Range
TO-244AB (ISOLATED)
Max.
400 111 53 600 1.4 179 71 -55 to +150
Units
V A mJ W C
Thermal - Mechanical Characteristics
Parameter
RthJC RthCS Wt Junction-to-Case, Single Leg Conducting Junction-to-Case, Both Legs Conducting Case-to-Sink, Flat , Greased Surface Weight Mounting Torque Terminal Torque Vertical Pull 2 inch Lever Pull
Min.
30 (3.4) 30 (3.4)
Typ.
0.10 79 (2.8)
Max.
0.70 0.35 40 (4.6) 40 (4.6) 80 35
Units
C/W K/W g (oz) lbfin (Nm) lbfin
Note: Limited by junction temperature L = 100H, duty cycle limited by max TJ 125C
Mounting surface must be smooth, flat, free or burrs or other protrusions. Apply a thin even film or thermal grease to mounting surface. Gradually tighten each mounting bolt in 5-10 lbfin steps until desired or maximum torque limits are reached. Module
1
HFA120MD40D
PD-2.508 rev. A 12/98
Electrical Characteristics (per Leg) @ TJ = 25C (unless otherwise specified)
Parameter
V BR V FM Cathode Anode Breakdown Voltage Max Forward Voltage
Min. Typ. Max. Units
400 1.0 1.2 1.2 1.4 0.90 1.1 1.0 6.0 1.5 8.0 180 260 7.0 V V A mA pF nH
Test Conditions
I R = 100A I F = 60A See Fig. 1 I F = 120A I F = 60A, TJ = 125C VR = VR Rated See Fig. 2 TJ = 125C, VR = 320V See Fig. 3 VR = 200V From top of terminal hole to mounting plane
IRM CT LS
Max Reverse Leakage Current Junction Capacitance Series Inductance
Dynamic Recovery Characteristics (per Leg) @ TJ = 25C (unless otherwise specified)
Parameter
trr trr1 trr2 IRRM1 IRRM2 Qrr1 Qrr2 di(rec)M/dt1 di(rec)M/dt2 Reverse Recovery Time
Min. Typ. Max. Units
Test Conditions
Peak Recovery Current Reverse Recovery Charge Peak Rate of Fall of Recovery Current During tb
36 IF = 1.0A, dif/dt = 200A/s, VR = 30V 90 140 ns TJ = 25C See 160 240 TJ = 125C Fig. 5 IF = 80A 9.3 17 TJ = 25C See A 15 30 TJ = 125C Fig. 6 VR = 200V 420 1100 TJ = 25C See nC 1200 3200 TJ = 125C Fig. 7 dif/dt = 200A/s 360 TJ = 25C See A/s 260 TJ = 125C Fig. 8
80.01 (3.150) 40.26 (1.585) 39.75 (1.565)
20.32 (0.800) 17.78 (0.700)
7.49 (0.295) 6.99 (0.275) DIA. (2 PLCS.)
34.925 (1.375) REF. 63.50 (2.500) 60.96 (2.400) 2
LEAD ASSIGNMENTS 1 - ANODE 2 - CATHODE 3 - ANODE
1/4-20 SLOTTED HEX
1
23.55 (0.927) 20.42 (0.804)
3
OUTLINE TO-244AB (ISOLATED)
Dimensions in Millimeters and (Inches)
15.75 (0.620) 14.99 (0.590)
92.71 (3.650) 90.17 (3.550)
3.35 (0.132) 3.02 (0.119)
2
HFA120MD40D
PD-2.508 rev. A 12/98
1000
10000
Reverse Current - IR (A)
1000
TJ = 150C T = 125C J
Instantaneous Forward Current - IF (A)
100
10
100
TJ = 150C TJ = 125C TJ = 25C
1
T = 25C J
0.1 0 100 200 300 400
Junction Capacitance - C T (pF)
10
Fig. 2 - Typical Reverse Current vs. Reverse Voltage, (per Leg)
10000
Reverse Voltage - VR (V)
A
T = 25C J
1000
1 0.4
0.8
1.2
1.6
2.0
Forward Voltage Drop - V FM (V)
Fig. 1 - Maximum Forward Voltage Drop vs. Instantaneous Forward Current, (per Leg)
1
100 1 10 100 1000
Reverse Voltage - VR (V)
Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage, (per Leg)
Thermal Impedance - Z thJC (K/W)
0.1
D = 0.50 D = 0.33 D = 0.25 D = 0.17
D = 0.08
P DM
t1 t2
0.01
Single Pulse (Thermal Resistance)
Notes: 1. Duty factor D = t / t 12 2. Peak TJ = PDM x Z thJC + TC
0.001 0.00001
0.0001
0.001
0.01
0.1
1
10
100
t 1, Rectangular Pulse Duration (Seconds)
Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics, (per Leg)
3
HFA120MD40D
PD-2.508 rev. A 12/98
240
100
VR = 200V TJ = 125C TJ = 25C
200
VR = 200V TJ = 125C TJ = 25C IF = 200A
t rr - (ns)
160
I IRRM - (A)
IF = 80A I F = 40A
10
I F = 200A I F = 80A
120
I F = 40A
80
40 100
di f /dt - (A/s)
1000
1 100
di f /dt - (A/s)
1000
Fig. 5 - Typical Reverse Recovery vs. dif/dt, (per Leg)
5000
Fig. 6 - Typical Recovery Current vs. dif/dt, (per Leg)
10000
VR = 200V TJ = 125C TJ = 25C
4000
VR = 200V TJ = 125C TJ = 25C
3000
IF = 200A I F = 80A
di(rec)M/dt - (A/s)
Q RR - (nC)
1000
I F = 40A I F = 80A IF = 200A
2000
IF = 40A
1000
0 100
di f /dt - (A/s)
1000
100 100
di f /dt - (A/s)
1000
Fig. 7 - Typical Stored Charge vs. di f/dt, (per Leg)
4
Fig. 8 - Typical di(rec)M/dt vs. dif/dt, (per Leg)
HFA120MD40D
PD-2.508 rev. A 12/98
3
IF
trr ta tb
4
REVERSE RECOVERY CIRCUIT
VR = 200V
0 Q rr I RRM
2
0.5 I RRM di(rec)M/dt
5
0.01 L = 70H D.U.T. D IRFP250 S
1
0.75 I RRM di f /dt
4. Qrr - Area under curve defined by trr and IRRM trr X IRRM Qrr = 2 5. di(rec)M/dt - Peak rate of change of current during tb portion of trr
dif/dt ADJUST G
1. dif/dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current
Fig. 9 - Reverse Recovery Parameter Test Circuit
L = 100H HIGH-SPEED SWITCH Rg = 25 ohm CURRENT MONITOR FREE-WHEEL DIODE + Vd = 50V
Fig. 10 - Reverse Recovery Waveform and Definitions
I L(PK)
DUT
DECAY TIME V (AVAL) V R(RATED)
Fig. 11 - Avalanche Test Circuit and Waveforms
WORLD HEADQUARTERS: EUROPEAN HEADQUARTERS: IR CANADA: IR GERMANY: IR ITALY: IR FAR EAST: IR SOUTHEAST ASIA: IR TAIWAN:
233 Kansas St., El Segundo, California 90245 U.S.A. Tel: (310) 322 3331. Fax: (310) 322 3332. Hurst Green, Oxted, Surrey RH8 9BB, U.K. Tel: ++ 44 1883 732020. Fax: ++ 44 1883 733408. 15 Lincoln Court, Brampton, Markham, Ontario L6T3Z2. Tel: (905) 453 2200. Fax: (905) 475 8801. Saalburgstrasse 157, 61350 Bad Homburg. Tel: ++ 49 6172 96590. Fax: ++ 49 6172 965933. Via Liguria 49, 10071 Borgaro, Torino. Tel: ++ 39 11 4510111. Fax: ++ 39 11 4510220. K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo, Japan 171. Tel: 81 3 3983 0086. 1 Kim Seng Promenade, Great World City West Tower,13-11, Singapore 237994. Tel: ++ 65 838 4630. 16 Fl. Suite D.207, Sec. 2, Tun Haw South Road, Taipei, 10673, Taiwan. Tel: 886 2 2377 9936.
http://www.irf.com
Fax-On-Demand: +44 1883 733420
Data and specifications subject to change without notice.
5


▲Up To Search▲   

 
Price & Availability of HFA120MD40D

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X